H200 Twin Alternating - Side Mount
H200 Twin/Triplex/Fourplex Installation - Side Mount
First-in, Last-Out Piping Arrangement.
Brine Tank
See NOTE Figure 7
Figure 6
Brine Tank(s)
Figure 7
NOTE:
System connections to the tank must accommodate longitudinal movement between side, top and bot-
tom openings, exibility in piping or ex connectors are recommended.
Red colored piping, ttings, and connectors are for reference only and are not included. Must be fur-
nished by others.
Union type connectors are recommended on the inlet and outlet connections.
1" Brine Line must be hard-piped, secured and supported for proper operation. CPVC or Schedule 80 PVC
recommended.
Inlet
Bypass Valve
Outlet
Isolation
Valves
MAV Valve
Inlet
Bypass Valve
MAV Valves
DLFC
Outlet
Isolation
Valves
Shut-Off Valve
MAV = Motorized Alternating Valve.
10
MAV = Motorized Alternating Valve.
Brine Tank(s)